Taiko-Input/QT-APP
AnalogDragon 366c8a7fca update
2023-07-30 00:03:35 +08:00
..
APP1_Taiko_IO_Setting update md 2023-06-23 04:08:42 +08:00
img update md 2023-06-23 04:08:42 +08:00
.gitignore Initial commit 2023-04-19 20:18:28 +08:00
README_EN.md update 2023-07-30 00:03:35 +08:00
README.md update 2023-07-30 00:03:35 +08:00

Host Computer

QT, WIN64
The host computer software is used to configure the parameters of the sampling microcontroller.

中文版

Home

Instructions

Screenshot Screenshot

Software Interface

  • A-Taiko sensor channel sequence configuration
  • B-Input configuration-Trigger threshold (triggering is done in hardware, no obvious effect in software configuration)
  • C-Input configuration-Multiplication factor (configure this when a certain sensor is exceptionally sensitive or insensitive, C for reset)
  • D-Output time configuration, H for hold time when pressing, L for hold time when releasing, no response to other inputs during hold time
  • E-Shielding configuration (used to calculate crosstalk caused by the physical structure of the taiko)
  • F-Shielding configuration-Single response (selecting this will trigger only one sensor each time)
  • G-Shielding configuration-Calculate rounds (set to 0 to disable calculation, directly trigger according to the fastest speed)
  • H-Some default parameters (for Taiko Force and arcade taiko)
  • I-Serial port selection
  • J-Select the parameter group on the upload board
  • K-Upload parameter button
  • L-Download parameter button (this step does not store data, data will be lost when the microcontroller is reset)
  • M-Save parameter button
  • N-Software status

Configuration Process

  • 1 Select the serial port, click upload, and the status will be displayed as Success (used to determine if the connection is successful)
  • 2 Reset the preset parameters according to your needs or upload old parameters
    • For modifications based on the old parameters, select Load Saved, and then press the upload parameter button
    • For modifications based on the default configuration, click the desired default configuration button (the two default configurations only differ in taiko mapping)
  • 3 After making modifications, click the download parameter button and confirm if the parameters are reasonable on the taiko
  • 4 Click the save parameter button

Other Instructions

  • When using single taiko hardware, the parameters for the second taiko are meaningless
  • Default configurations may have issues; you can make fine adjustments based on the default parameters to suit your taiko
  • The sensor wire sequence of the taiko can be remapped through this APP.