Adding Files for Hardware - Updating Readme

This commit is contained in:
-help 2024-02-10 04:12:09 +02:00
parent d2b1d63d85
commit 91186894da
19 changed files with 32863 additions and 4 deletions

Binary file not shown.

File diff suppressed because one or more lines are too long

View File

@ -24,8 +24,8 @@ This repository contains the source code and design files for a Solder Plate Con
- Included files for a case and guard for the detachable plate terminal guard
![Screenshot](/Renders/Controller%201mos.JPG)
![Screenshot](/Renders/plate%201%20zone.JPG)
![Screenshot](/Renders/1 zone side.png)
![Screenshot](/1 zone plate side.png)
@ -95,7 +95,7 @@ JCM from the Discord explained the process pretty good:
1. Order 100K NTC Glass thermistors Use for dev was : 100K Ohm Resistor NTC 3950-> https://www.aliexpress.com/item/32862228715.html?spm=a2g0o.order_list.order_list_main.11.1f0a1802Lw8YGL
2. Using either the potentiometer or soldering the resistor beside it choose the resistor reference value (2.5Kohm is standard)
3. You can modify the thermistor settings in Global.ccp file, it is all explained in there
4. Attach the sensors to the hotplate using High tem Kapton Tape
4. Attach the sensors to the hotplate using High temp Kapton Tape
5. Reccomended is 3 sensors on the bottom middle of plate all with 3 different refernece resistor values for accuracy across all temperature ranges and 1 thermistor held by a pair of helping hangs placed so the head touches somewhere on the PCB to be refllowed
By default this is set as thermistor 1:
@ -106,7 +106,7 @@ JCM from the Discord explained the process pretty good:
- Thermistor thermistor3(THERMISTOR3_PIN, 9100, ThermistorZ_Placement::BOTTOM, ThermistorXY_Placement::MIDDLE_LOW_TEMP); -> 9100Kohm set refrence
- Thermistor thermistor4(THERMISTOR4_PIN, 564, ThermistorZ_Placement::BOTTOM, ThermistorXY_Placement::MIDDLE_HIGH_TEMP);-> 564Kohm set refrence
These settings are measured between a GND point anywhere on the board and the LEFT pin of the connector with the thermistor UNPLUGGED
The set resistence is measured between a GND point anywhere on the board and the LEFT pin of the connector with the thermistor UNPLUGGED
you can measure and set those to the preset values or modify the values in globals.ccp to match your thermistors.

BIN
Renders/1 zone back.png Normal file

Binary file not shown.

After

Width:  |  Height:  |  Size: 430 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 254 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 393 KiB

Binary file not shown.

After

Width:  |  Height:  |  Size: 358 KiB

BIN
Renders/1 zone side.png Normal file

Binary file not shown.

After

Width:  |  Height:  |  Size: 790 KiB

BIN
Renders/1 zone top.png Normal file

Binary file not shown.

After

Width:  |  Height:  |  Size: 670 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 217 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 192 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 197 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 181 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 162 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 178 KiB